Imada Cap Torque Tester (DTXA/DTXS Series)

Share:


Imada Cap Torque Tester (DTXA/DTXS Series)

Imada Screw cap torque tester (torque gauge) DTXS series is standard type offering highly repeatable torque measurements with 50N-cm to 10N-m(1000N-cm) capacity. by MSP Metrology (M) Sdn Bhd from Imada Japan


Features



Standard Type Screw Cap Torque Tester (Torque Gauge)

DTXA/DTXS Series

Screw cap torque tester (torque gauge) DTXS series is standard type offering highly repeatable torque measurements with 50N-cm to 10N-m(1000N-cm) capacity. It is ideal for measuring opening/closing torque of various samples such as bottles. It comes with data logging software for easy data management.
 

Feature 1: Saves data to the internal memory

Saves data to the internal memory. (Max.1000 data)
Enables to print out the all saved data by using RS232C printer

Feature 2: High repeatability by high speed sampling

The high speed data sampling rate (2000 data / sec) captures momentary force and digitizes it.
It captures the right max value and enhances repeatability of repeat test.

Feature 3: Enables to measure various samples by various attachments

Changeable pins, tables and attachments. The users can choose the most suitable combination for their sample


Feature 4: Useful functions improving work efficiency
 

Organic Electroluminescence Display

The display is visually clear as the user can see it from the side or in a dark place.

Various Display

Time display

Easy and certain data managements

Bar graph
For prevention of breaking the sensor(over load). (*1)

Captures Data to PC by included software

Display Force value/Date and time/ OK/NG judgment by connecting PC via USB

Stable Body Fixation

The body can be fixed on a desk with the carry handle holes. It supports testing stable. 


Standard Features


  • High sampling rate (2000Hz) for accurate results, capturing small changes and accurate peak values by following rapid changes of torque
  • Easy data management using supplied software Force Logger via USB connection to PC
  • Reduces risk of misreading values with easy-to-read high luminance organic EL display
  • Handles a wide range of samples with various optional tables and attachments
  • Optional software Force Recorder Light/Standard available for real-time graphing of torque vs. time at 2000 data/sec on PC, visualizing small changes of torque for detailed analysis of results



Specifications


Model  DTXS  DTXA
Outline Standard model with various functions Advanced model with additional functions of
DTXS series. Such as input/output angles and
saving to USB flash drive etc.
Accuracy ±0.5%F.S.±1digit
Unit of measurement N-m, N-cm, kgf-m, kgf-cm, lbf-in, ozf-in (Unit switching is possible.)(*1)
Display 4-digit
Display update 16 times /sec
Sampling rate Maximum 2000 data/ sec(*2)
Battery 8 hours (2 hours full charge)(*3)
Safe overload rating Approx. 200%
Operating Environment Temperature: 0 – 40 degree Celsius Humidity: 20 -80%RH
Function Customized display(header and footer) / Peak hold(Clockwise and Counterclockwise)/
Internal memory(1000 point data)) / Comparator (OK or NG judgment)/
Reversible display/ Sign inversion/ Zero clear timer/ +NG alarm/
Off timer(Auto power off)/ Dumping/ Time display/ setting lock
1st2nd peak/
Angle detection at torque peak value(*4) /
Angle zero reset at selected torque(*4)
Output USB, RS232C, Mitutoyo digimatic (*5), 2 VDC analog output (D/A),
Comparator 3 steps (-NG/OK/+NG), Overload alarm
Sub comparator 2 steps (output of large or
small judgment), USB flash drive,
Angle(displacement)
Overload warning Approx.110%F.S. (Warning message and alarm)
External connecting
switch
SEND (a point of contact holding), Zero reset, Peak ON/OFF setting
Weight Approx. 3.0kg (No table model), Approx. 4.5kg (Included standard table and pins)
Dimensions See [Dimensions]
Accessory AC adapter, Inspection certificate, CD driver (including simple software for data
logging),USB cable, Carrying case, L wrench
USB flash drive adapter(*6)
Approved standard JIS S 0022 (2001)
Guidelines for all people including elderly and people with disabilities — Packaging and
receptacles — Test methods for opening “6.3 Screw top receptacle”

*1 These are the specifications for International model. Please note that this unit is different from Japanese domestic model.
*2 Up to 100 data/sec. is saved in USB memory (selectable among 1, 50, and 100 /sec)
*3 The battery is more consumed when connected to USB flash drive or a displacement scale.
*4 Angle(displacement) scale is necessary to valid this function.
*5 Not always available for Mitutoyo digimatic products.
*6 USB flash drive is not included.

 
DTXS Japan Model (US Model) DTXA (Japan Model only) Range Display Resolution
DTXS-0.5N-Z (*1) (*2) (DTXS-4-Z) DTXA-0.5N-Z (*1) (*2) 0.5 N-m (50N-cm) 50.00N-cm 0.01N-cm
DTXS-2N (DTXS-15) DTXA-2N 2 N-m (200N-cm) 2.000N-m (200.0N-cm) 0.001N-m (0.1N-cm)
DTXS-5N (DTXS-40) DTXA-5N 5 N-m (500N-cm) 5.000N-m (500.0N-cm) 0.001N-m (0.1N-cm)
DTXS-10N (DTXS-85) DTXA-10N 10N-m (1000N-cm) 10.00N-m (1000N-cm) 0.01N-m (1N-cm)
DTXS-2N-Z (*1) (DTXS-15-Z (*1)) DTXA-2N-Z (*1) 2 N-m (200N-cm) 2.000N-m (200.0N-cm) 0.001N-m (0.1N-cm)
DTXS-5N-Z (*1) (DTXS-40-Z (*1)) DTXA-5N-Z (*1) 5 N-m (500N-cm) 5.000N-m (500.0N-cm) 0.001N-m (0.1N-cm)
DTXS-10N-Z (*1) (DTXS-85-Z (*1)) DTXA-10N-Z (*1) 10N-m (1000N-cm) 10.00N-m (1000N-cm) 0.01N-m (1N-cm)
 

Related Videos



Japan IMADA Screw Cap Torque Tester : DTX Series

Japan IMADA Screw Cap Torque Tester DTX Series : Data Collection/Management


 Inquiry - Imada Cap Torque Tester (DTXA/DTXS Series)

GET IN TOUCH
10, Jalan Gemilang 9, Taman Perindustrian Cemerlang, 81800 Ulu Tiram, Johor, Malaysia.
+607-862 6772
STAY CONNECTED
LIKE & FOLLOW US